Show/Hide Toolbars

CWT Software Configuration Handbook

Note:
It is possible to use Battery Low (32:103) and Battery Empty (32:104) instead of Measured Voltage (32:213).
To enable Battery Low and Battery Empty events. Use the following event-configuration.

<EVENT>
 <event unit="32" code="103" level="Enable"/> <!-- Battey low -->
 <event unit="32" code="104" level="Enable"/> <!-- Battery empty -->
 <event unit="32" code="213" level="None"/>  <!-- Measured voltage -->
</EVENT>

Details:

New EVENT_CODE_BATTERY_LOW

BATTERY_LOW is set to Warning if battery voltage is below warning level.

BATTERY_LOW is kept to Warning if battery voltage is below error level.

BATTERY_LOW is set to Reset if battery voltage is above recovery level.

New EVENT_CODE_BATTERY_EMPTY

BATTERY_EMPTY is set to Error if battery voltage is below error level.

BATTERY_EMPTY is set to Reset is battery voltage is above warning level.

BATTERY_EMPTY is never set to Warning.