Please enable JavaScript to view this site.

WebOffice  2.66 Complete Guide

Navigation: Terminal Administration > Terminals

Terminal Measurements.

Scroll Prev Top Next More
MenuTerminal Administration -> [+] Terminals -> Terminal Measurements.

LicenseKeyMediumA terminal can be configured to send measurement data to WebOffice.  

 

Reference
See CWT Software Configuration Handbook for how to set up a terminal to send measurements to WebOffice.
Note:
This page uses Enforced filtering. You must select a Measure Time Terminal Local before you can display the list.
Select the period you want to see. This is default set to Dynamic Time Span – Last 24 Hours.
CA9992~1_img202

The following measurements can be sent:

Measurement Type

Value displayed in

CWT

MAX

Battery voltage.

Actual Value in Voltage of the main battery.

X

X

Backup battery voltage.

Actual Value in Voltage of the backup battery.

 

X

Main board temperature.

Actual value in Degrees Celsius.

X

 

Model Signal Strength.

In percentage of the maximal signal strength.

4G:

oWorst signal strength = -140 dBm.

oBest signal strength = -44 dBm.

3G:

oWorst signal strength = -120 dBm.

oBest signal strength = -50 dBm.

2G:

oWorst signal strength = -113 dBm.

oBest signal strength = -50 dBm.

X

X

SD Card Memory.

In Percentage of the total space.

X

 

Sleep mode current.

Actual value in mA.

X

 

Solar Panel current.

Actual Value in mA.

X

 

Termination board Temperature (CWT 21XX series only).

Actual value in Degrees Celsius.

X

 

Note:
In CWT version 2.34, the Modem signal strength can only be measured during start-up.  If the sampling period is set to 1 or larger, this initial value will be sent to WebOffice every time the terminal sends the data