Menu | Terminal Administration -> [+] Terminals -> Terminal Measurements. |
A terminal can be configured to send measurement data to WebOffice.
Reference See CWT Software Configuration Handbook for how to set up a terminal to send measurements to WebOffice. |
Note: This page uses Enforced filtering. You must select a Measure Time Terminal Local before you can display the list. Select the period you want to see. This is default set to Dynamic Time Span – Last 24 Hours. |
The following measurements can be sent:
Measurement Type |
Value displayed in |
CWT |
MAX |
---|---|---|---|
Battery voltage. |
Actual Value in Voltage of the main battery. |
X |
X |
Backup battery voltage. |
Actual Value in Voltage of the backup battery. |
|
X |
Main board temperature. |
Actual value in Degrees Celsius. |
X |
|
Model Signal Strength. |
In percentage of the maximal signal strength. •4G: oWorst signal strength = -140 dBm. oBest signal strength = -44 dBm. •3G: oWorst signal strength = -120 dBm. oBest signal strength = -50 dBm. •2G: oWorst signal strength = -113 dBm. oBest signal strength = -50 dBm. |
X |
X |
SD Card Memory. |
In Percentage of the total space. |
X |
|
Sleep mode current. |
Actual value in mA. |
X |
|
Solar Panel current. |
Actual Value in mA. |
X |
|
Termination board Temperature (CWT 21XX series only). |
Actual value in Degrees Celsius. |
X |
|
Note: In CWT version 2.34, the Modem signal strength can only be measured during start-up. If the sampling period is set to 1 or larger, this initial value will be sent to WebOffice every time the terminal sends the data |