Show/Hide Toolbars

CWT Compact S2 Installation & Maintenance Manual

Place the battery on the floor in the bottom of the pedestal.

Important:
The RED coloured lead must be attached to the PLUS pole on the battery. Connecting with wrong polarity will blow one or more fuses on the CPU board and will result in unrepairable damages to the Main board.

in a mains-powered terminal

Connect the battery to the 12 V distribution panel on the battery charger to the connector marked

Figure 33, Connection of battery to 12V distribution panel

Figure 33, Connection of battery to 12V distribution panel

 

in a solar or battery-only powered terminal

Connect the 12 V supply cable from connectors J5 and J14 on the CPU board to the battery.

Solar Power Connections