Show/Hide Toolbars

CWT Software Configuration Handbook

Value        Path: <cwt><PRINTER><ttp2030><attributes><attribute id="39" >

Specifies the length of the black mark in 0.125 mm steps. Measure the length of the black mark on your paper and enter that value.

Detected black areas 5 mm longer than the set value will be interpreted as paper out.

Default value: 50 (equal to 6.25 mm).

Use max black mark length

Value range

Note

True

False

Non default setting is used. See 4.5.19.2 below. Recommended setting.

Default setting (80) is used.

max black mark length value

Value range

Note

1 – 159

Min. black mark length in 0.125 mm steps. Recommended setting: 30

Example:

<attribute id="39" value="80" use="false" description="Max black mark length" min="1" max="160" />